Exhaust with 3-Sided PSP Make-Up Air Full Capture and Containment
 
Gas CharBroiler (700°F) Electric Griddle (400°F)
  • Exhaust rate = 2500 CFM (313 CFM/lnft)
  • Supply rate = 1900 CFM (100 CFM/lnft)
  • Exhaust rate = 1400 CFM (175 CFM/lnft)
  • Supply rate = 1200 CFM (63 CFM/lnft)
[ Download Video ]
 
[ Download Video ]
 
 
Gas CharBroiler (700°F)  
  • Exhaust rate = 3900 CFM (488 CFM/lnft)
  • Supply rate = 2850 CFM (150 CFM/lnft)
 
[ Download Video ]
 
 
 
Gas CharBroiler with End Panels (700°F)  
  • Exhaust rate = 3300 CFM (413 CFM/lnft)
  • Supply rate = 2850 CFM (150 CFM/lnft)
 
[ Download Video ]
 
 
Exhaust with Front PSP Make-Up Air Full Capture and Containment
 
Gas CharBroiler (700°F) Electric Griddle (400°F)
  • Exhaust rate = 2700 CFM (338 CFM/lnft)
  • Supply rate = 1520 CFM (190 CFM/lnft)
  • Exhaust rate = 1450 CFM (182 CFM/lnft)
  • Supply rate = 1200 CFM (150 CFM/lnft)
[ Download Video ]
 
[ Download Video ]