Rep Our Products

Are you interested in representing CaptiveAire and selling our products?
Please fill out the following form, and we will contact you soon.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
CAH 22 with 30" burner Parts
Motors, Pulleys, & Motor Specific Parts
Click on a part # to order that part.
Motor HP Phs Voltage FLA Shaft Frame Weight RPM Vendor
00518OS1C184T 5.000 1 208-230 V 27.1-24.6 1.125" 184T 99 lbs 1750 Weg
ODP (Open Drip Proof) Pulleys
Show parts
00518OT3H184T-S 5.000 3 575 V 5 1.125" 184T 80 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0054 5.000 3 190/200-208-230/380/400/415/460 V 17/15.6-15-13.6/8.5/7.7/7.5/6.8 1.125" 184T 77 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP7/54 7.500 3 200-208-230/380/400/460 V 21.5-21.1-19.1/11.4/10.8/9.6 1.375" 213T 104 lbs 1750 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
00718OT3H213T-S 7.500 3 575 V 7.4 1.375" 213T 116 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0104 10.000 3 190/208-230/380/460 V 29.9/27-24.4/15/12.2 1.375" 215T 164 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
01018OT3H215T-S 10.000 3 575 V 9.9 1.375" 215T 137 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
01518OT3H254T-S 15.000 3 575 V 14.9 1.625" 254T 175 lbs 1750 WEG
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0154-50 15.000 3 190/380 V 44.9/22.5 1.625" 254T 230 lbs 1454 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0154 15.000 3 208-230/380/460 V 40.3-36.4/22.7/18.2 1.625" 254T 231 lbs 1755 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
DTP0204 20.000 3 208-230/460 V 53.7-48.6/24.3 1.625" 256T 269 lbs 1770 Mimco/TECO
ODP, Premium (E-Plus3) Eff. Pulleys
Show parts
XP7/54 7.500 3 208-230/460 V 19.6-17.7/8.8 1.375" 213T 187 lbs 1800 Mimco/TECO
Explosion Proof Pulleys
Show parts
00518ET3H184T-W22 5.000 3 575 V 5.1 1.125" 184T 104 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
00718ET3H213T-W22 7.500 3 575 V 7.3 1.375" 213T 174 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
GP7/54 7.500 3 190/200-208-230/380/400/460 V 22.4/21.4-20.5-18.5/11.2/10.7/9.3 1.375" 213T 117 lbs 1800 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
01018ET3H215T-W22 10.000 3 575 V 9.9 1.375" 215T 188 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
GP0104 10.000 3 190/200-208-230/380/400/460 V 29.6/27.8-26.6-24/14.8/13.9/12 1.375" 215T 159 lbs 1755 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0154 15.000 3 190/208-230/380/460 V 41.8/38.2-34.5/20.9/17.3 1.625" 254T 250 lbs 1765 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
01518ET3H254T-W22 15.000 3 575 V 14.4 1.625" 254T 347 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02018ET3H256T-W22 20.000 3 575 V 19.3 1.625" 256T 396 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
02018ET3H256T-S 20.000 3 575 V 19.8 1.625" 256T 227 lbs 1750 WEG
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts
NP0204 20.000 3 190/208-230/380/460 V 55.7/50.8-46/27.8/23 1.625" 256T 287 lbs 1760 Mimco/TECO
TEFC, Premium (E-Plus3) Eff. Pulleys
Show parts

The manufacturer reserves the right to use alternate motors from alternate vendors that meet the operating requirements of the fan but may have slightly different specifications.
Intakes & Intake Parts
Click on a part # to order that part.
Part Per Unit List 
IH3-O-FDH Full downturn intake hood. 76.25" wide, 52" deep, 46.75" high. $1,323.33
IH3-O-IHNF Intake Hood - 76.25" Width X 69.50" Length X 46.75" Height $882.22
Show parts
IH3-O-IH2"EZ Intake Hood Outdoor - 76.25" Width X 69.50" Length X 46.75" Height With 2" EZ Filter Max CFM = 24438 $1,115.90
Show parts
IH3-O-VB2"TA-FDH V-BANK - 76.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 8 Filters $2,323.01
Show parts
IH3-O-VB2"EZ-IH2"EZ V-BANK - 76.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood $2,304.25
Show parts
IH3-O-VB2"TA-IH2"EZ V-BANK - 76.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood MERV 8 Filters $2,170.57
Show parts
IH3-I-VB2"TA V-BANK - 76.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 8 Filters $1,054.65
Show parts
IH3-I-VB2"TA13 V-BANK - 76.25" Width X 28" Length X 46.75" Height for Horizontal Industrial With Standard 2" Pleated Filter MERV 13 Filters $1,622.45
Show parts
IH3-I-VB2"EZ V-BANK - 76.25" Width X 28" Length X 46.75" Height for Industrial Horizontal With Standard 2" EZ Filter $1,188.36
Show parts
IH3-O-VB2"TA13-FDH V-BANK - 76.25" Width X 80" Length X 46.75" Height, Standard 2" TA Filter With Full Downturn Hood MERV 13 Filters $2,890.78
Show parts
IH3-O-VB2"EZ-IHNF V-BANK - 76.25" Width X 95.50" Length X 46.75" Height With Standard 2" EZ Filter And Intake Hood w/ No Filters $2,070.59
Show parts
IH3-O-VB2"TA13-IHNF V-BANK - 76.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 13 Filters $2,504.67
Show parts
IH3-O-VB2"TA13-VB2"TA-IHNF V-BANK - 76.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 13 Filters $3,558.56
Show parts
IH3-O-VB2"TA-IHNF V-BANK - 76.25" Width X 95.50" Length X 46.75" Height With Standard 2" Pleated Filter w/Intake Hood w/No Filters MERV 8 Filters $1,936.88
Show parts
IH3-O-VB2"TA13-IH2"EZ V-BANK - 76.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood MERV 13 Filters $2,738.34
Show parts
IH3-O-VB2"TA13-VB2"TA-IH2"EZ V-BANK - 76.25" Width X 97.5" Length X 46.75" Height, Standard 2" EZ Filter With Intake Hood MERV 13 Filters $3,991.43
Show parts
Temperature Controls
Click on a part # to order that part.
Part Per Unit List
0-150°F Discharge Temp Control • Heating Activation Based On Intake Set Point • Manual Blower Mode. Includes Remote HMI. Use with MUA. (R-DISCHARGE-INTAKE-0-150-MANUAL-RP-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Intake Set Point Manual Blower Mode Additional HMI Ships Loose  
0-150°F Industrial Discharge Temp Control • Field Wired On/Off Start Command • Heating Activation Based On Intake Set Point. Includes Remote HMI. Use with MUA. (R-DISCHARGE-INTAKE-0-150-FS-RP-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Blower Discharge Field Wired On/Off Start Command Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Intake Set Point Additional HMI Ships Loose  
0-150°F Industrial Discharge Temp Control • Field Wired On/Off Start Command • Heating Activation Based On Intake Set Point. Use with MUA (R-DISCHARGE-INTAKE-0-150-FS-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Blower Discharge Field Wired On/Off Start Command Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Intake Set Point  
401M • Series 14 Remote Panel with On/Auto Switch & Time Clock • 40-80 Dial • Indicating Lights (R-401M-S14-40-80-On-Auto-Time Clock)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control With Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Remote Panel Includes On/Auto Switch and Indicator Lights Auto Mode Cycled by Time Clock Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 Remote Panel with On/Off/Auto Switch & Time Clock • 40-80 Dial • Indicating Lights (R-401M-S14-40-80-On-Off_Auto-Time Clock)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control With Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Auto Mode Cycled by Time Clock Remote Panel Includes On//Off/Auto Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 Remote Panel with On-Auto Switch, Lights & 40-80°F Dial (R-401M-S14-40-80-On-Auto)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control With Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Remote Panel Includes On/Auto Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 Remote Panel with On-Off-Auto Switch, Lights & 40-80°F Dial (R-401M-S14-40-80-On-Off-Auto)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control With Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Remote Panel Includes On/Off/Auto Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
401M • Series 14 Remote Panel with S/O/W Switch, Lights & 40-80°F Dial (R-401M-S14-40-80)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control With Remote Panel 40-80°F Discharge Temperature Set-Point Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
402M • Series 14 Remote Panel with S/O/W Switch, Lights & 40-80°F Dial & Room Override (40° Max) Discharge Control (R-402M-S14-40-80-RO)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control with Remote Panel and Room Override Thermostat 40-80°F Discharge Temperature Set-Point 40°F Room Overide Mounted on Separate Remote Panel Discharge Set-Point Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge 40°F Room Override Mounted on Separate Remote Panel Remote Panel Includes Summer/Off/Winter Switch and Indicator Lights Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point  
Show parts
403M • Series 44 Remote Panel with S/O/W Switch, Lights & 55-90°F Dial & Constant Operation Space Heating Control (R-403M-S44-55-90-COR)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 120°F Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
404M • Series 44 Remote Panel with S/O/W Switch, Lights & Occupied-Unoccupied Space Heating Control (R-404M-S44-55-90-D&NSPH)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control with Remote Panel 55-90°F Range Modulating Space Slectrastat Mounted on Remote Panel Discharge Sensor Mounted in Blower Discharge Minimum Discharge Set-Point 40-80°F, Factory Set at 60°F Maximum Discharge Set-Point 80-140°F, Factory Set at 120°F Occupied-Unoccupied Space Heating Control Remote Panel Includes Summer/Off/Winter Switch, Selectrastat, and Indicator Lights Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point  
Show parts
50-90°F Industrial Space Temp Control • Field Wired On/Off Switch Control • Heating Activation Based On Either Intake or Space Set Point. Use with MUA. (R-SPACE-EITHER-50-90-FS-MUA)  
  50-90°F Range Modulating Space Temperature Control Unit Maximum Discharge 120°F Space HMI Shipped Loose for Room Mounting Field Wired On/Off Start Command Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point  
50-90°F Industrial Space Temp Control • Heating Activation Based On Either Intake or Space Set Point • Manual Blower Mode. Use with MUA. (R-SPACE-EITHER-50-90-MANUAL-MUA)  
  50-90°F Range Modulating Space Temperature Control Unit Maximum Discharge 120°F Space HMI Shipped Loose for Room Mounting Modulating Temperature Control System Designed to Maintain Space Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
Building Management Signal • 0 to 10VDC or 4-20mA Heating Signal • Not For Use with Pre-Wire. Use with MUA. (R-BMS-MUA)  
  Building Management System That Receives a 0-10VDC or 4-20mA Signal for Heat Modulation Blower Start/Heat Start/Cooling Start 24VAC Terminals on Board Modulating Temperature Control System  
Building Management Signal • 0 to 10VDC or 4-20mA Signal Conditioner • Blower/Heat/Cooling Relays (R-BMS)  
  Building Management System That Receives a 0-10VDC or 4-20mA Signal for Heat Modulation Blower Start/Heat Start/Cooling Start 24VAC Relays Included Modulating Temperature Control System  
Show parts
Building Management Signal RCS • 0 to 10VDC or 4-20mA Heating Signal • Not For Use with Pre-Wire. Use with MUA. (R-RCS-BMS-MUA)  
  Building Management System That Receives a 0-10VDC or 4-20mA Signal for Heat Modulation Blower Start/Heat Start/Cooling Start 24VAC Terminals on Board Modulating Temperature Control System  
Maxitrol "M" Series Programmable Control • High Temp No Remote Ship Loose Component(s). (R-M Series No Remote)  
  Maxitrol "M" Series Programmable Controller.  
Show parts
Paint Booth • Maxitrol "M" Series Programmable Control • Cure Only • High Temp (R-PB-C-1-M Series)  
  Maxitrol "M" Series Programmable Controller. Cure Only Controls 1 or 2, Single Speed Booth Exhasut Fans "On" Push Button "M" Series Control Start Delay Timer Power On Light Blower On Light Burner On Light Flame Failure Light Fire System Interlocks Cure Timer Cure Light Cool Down Cycle with Light Lights Out During and After Cure Solenoid Lockout during Cure  
Show parts
Paint Booth • Maxitrol "M" Series Programmable Control • Spray Only • High Temp (R-PB-S-1-M Series)  
  Maxitrol "M" Series Programmable Controller. Spray Only Controls 1 or 2, Single Speed Booth Exhasut Fans "On" Push Button "M" Series Control Start Delay Timer Power On Light Blower On Light Burner On Light Flame Failure Light Fire System Interlocks Solenoid Interlocks Spray Light  
Show parts
Paint Booth • Maxitrol "M" Series Programmable Control • Spray/Cure • High Temp (R-PB-SC-1-M Series)  
  Paint Booth Remote Control Panel. Power, Blower, Burner, Spary, Cure, Purge, Cool Down and Flame Failure Lights. Fire System and Spray mode Interlocks.  
Show parts
Paint Booth • Maxitrol "M" Series Programmable Control • Spray/Flash/Cure • High Temp (R-PB-SFC-1-M Series)  
  Paint Booth Remote Control Panel. Power, Blower, Burner, Spary, Cure, Purge, Cool Down and Flame Failure Lights. Fire System and Spray mode Interlocks.  
Show parts
Series 14 Discharge Control, For ECP or Field Wired On/Off Switch, No Remote Panel, 40-80°F (R-S14-40-80)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control No Remote Panel, Use With Non_DCV Pre-Wire or Field Wired Switch Single Range - 40°F to 80°F Discharge Temperature Set-Point Set-Point Mounted in Unit Discharge Sensor Mounted in Blower Discharge  
Show parts
XGFS • 401M PLC Series 14 Specialized Control System • Canada • High Temp (R-GFS-401M-S14-40-80-PLC-CANADA)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge Remote Panel & PLC Interface by GFS Canada Requirements  
Show parts
XGFS • 401M PLC Series 14 Specialized Control System • High Temp (R-GFS-401M-S14-40-80-PLC)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge Remote Panel & PLC Interface by GFS  
Show parts
XGFS • 401M Series 14 On/Off/Auto Building Dump Control System (R-GFS-401M-S14-BUILDING DUMP)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge  
Show parts
XGFS • 401M Series 14 On/Off/Auto Building Dump Control System Canada (R-GFS-401M-S14-BUILDING DUMP-CAN)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge  
Show parts
XGFS • 401M Series 14 Specialized Control System (R-GFS-401M-S14-40-80)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge Remote Panel by GFS  
Show parts
XGFS • 401M Series 14 Specialized Control System • Canada (R-GFS-401M-S14-40-80-CANADA)  
  Maxitrol Series 14 Electronic Modulating Discharge Temperature Control 40-80°F Discharge Temperature Set-Point Discharge Sensor Mounted in Blower Discharge Remote Panel by GFS Canda Requirements  
Show parts
XGFS • 403M Series 44 Specialized Control System (R-GFS-403M-S44-40-80-COR)  
  Maxitrol Series 44 Electronic Modulating Space Temperature Control Minimum Discharge Set-Point 20-60°F, Factory Set at 60°F Maximum Discharge Set-Point 60-120°F, Factory Set at 120°F Discharge Sensor Mounted in Blower Discharge Remote Panels by GFS  
Show parts
XGFS • 7EC PLC Signal Conditioner • High Temp • Canada (R-GFS-SC-PLC-CANADA)  
  SC11 Signal Conditioner Discharge Sensor Mounted in Blower Discharge Spray/Cure Control Remote Panel & PLC Interface by GFS Canada Requirements  
Show parts
XGFS • 7EC PLC Signal Conditioner • High Temp • NFPA86 (R-GFS-SC-PLC)  
  SC11 Signal Conditioner Discharge Sensor Mounted in Blower Discharge Spray/Cure Control NFPA 86 Remote Panel & PLC Interface by GFS  
Show parts
XGFS • 7EC Signal Conditioner • High Temp (R-GFS-SC)  
  7EC Signal Conditioner that uses 4-20mA or 0-10v control. Remote Panels & Controls By Others  
Show parts
XGFS • HMI Building Dump • Heating Activation Based On Either Intake or Space Set Point • Manual Blower Mode. Use with MUA (R-GFS-DIS-EITHER-0-150-MANUAL-MUA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
Show parts
XGFS • HMI Building Dump Canada • Heating Activation Based On Either Intake or Space Set Point • Manual Blower Mode. Use with MUA (R-GFS-DIS-EITHER-0-150-MANUAL-CANADA)  
  0-150°F Range Modulating Discharge Temperature Control Unit Maximum Discharge 150°F Discharge Set Point Mounted in Heater Discharge Sensor Mounted in Discharge of Unit Modulating Temperature Control System Designed to Maintain Discharge Temperature Set-Point Heating Activation Based On Either Intake or Space Set Point Manual Blower Mode  
Show parts
XGFS Velocity Control Package • PLC Signal Conditioner • High Temp • Canada (R-GFS-VCP-SC-PLC-CANADA)  
  SC11 Signal Conditioner Spray/Cure Control VFD Mounted in MAU Remote Panel & PLC Interface by GFS Canada Requirements  
Show parts
XGFS Velocity Control Package • PLC Signal Conditioner • High Temp • NFPA86 (R-GFS-VCP-SC-PLC)  
  SC11 Signal Conditioner Spray/Cure Control VFD Mounted in MAU NFPA 86 Remote Panel & PLC Interface by GFS  
Show parts
Gas Manifold Parts
Click on a part # to order that part.
Part Per Unit List
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1212  
2475000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1212  
2475000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 5774999 BTU
Show parts
5775000 - 6324999 BTU
Show parts
6325000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1212  
2475000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 5774999 BTU
Show parts
5775000 - 6324999 BTU
Show parts
6325000 - 7974999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Ind Gas Man - 14 in. w.c. - 1 lb., FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1212  
2475000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 6874999 BTU
Show parts
6875000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-66  
0 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1010  
1925000 - 2199999 BTU
Show parts
2200000 - 2474999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1212  
2475000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-1616  
2750000 - 4124999 BTU
Show parts
4125000 - 6874999 BTU
Show parts
6875000 - 7974999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 549999 BTU
Show parts
550000 - 824999 BTU
Show parts
825000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 14 in. w.c. - 1 lb., No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 1924999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., FM Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts
2500000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement (ANSI), BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement (ANSI), BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement (ANSI), BV250-66  
0 - 824999 BTU
Show parts
825000 - 1000000 BTU
Show parts
1000001 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement (ANSI), BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement with Proof of Closure, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement with Proof of Closure, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement with Proof of Closure, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 1 lb. - 5 lb., No Insurance Requirement with Proof of Closure, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FIA/IRI Insurance Requirement, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FIA/IRI Insurance Requirement, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FIA/IRI Insurance Requirement, BV250-66  
0 - 399999 BTU
Show parts
400000 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FIA/IRI Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2749999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement, BV250-1010  
2750000 - 3574999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement, BV250-1212  
3575000 - 4124999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement, BV250-66  
0 - 824999 BTU
Show parts
825000 - 999999 BTU
Show parts
1000000 - 1374999 BTU
Show parts
Industrial Gas Manifold - 5 lb. - 10 lb., FM Insurance Requirement, BV250-88  
1375000 - 1649999 BTU
Show parts
1650000 - 2199999 BTU
Show parts
2200000 - 2499999 BTU
Show parts