Performance Table |
CFM | Static Pressure in Inches W.G. |
---|
0.000 | 0.250 | 0.500 | 0.750 | 1.000 | 1.250 | 1.500 | 1.750 | 2.000 | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP |
13000 | 123 3.2 / 0.32 | 203 6.7 / 1.22 | 261 9.0 / 2.35 | 308 11.1 / 3.61 | 348 12.7 / 4.97 | 384 14.3 / 6.44 | 416 15.5 / 8.00 | 446 16.9 / 9.67 | 474 18.6 / 11.42 |
16000 | 151 5.2 / 0.59 | 221 7.4 / 1.66 | 274 9.6 / 2.92 | 320 11.5 / 4.33 | 359 13.2 / 5.86 | 395 14.7 / 7.47 | 427 16.0 / 9.17 | 456 17.5 / 10.95 | 484 19.3 / 12.81 |
19000 | 180 5.8 / 0.99 | 241 8.1 / 2.23 | 290 10.3 / 3.61 | 333 12.0 / 5.17 | 371 13.7 / 6.85 | 406 15.2 / 8.63 | 438 16.4 / 10.48 | 467 18.2 / 12.41 | 495 19.9 / 14.41 |
22000 | 208 6.9 / 1.53 | 264 9.2 / 2.98 | 308 11.1 / 4.48 | 348 12.7 / 6.16 | 385 14.3 / 7.99 | 418 15.6 / 9.92 | 449 17.1 / 11.93 | 477 18.8 / 13.89 | |
25000 | 236 7.9 / 2.24 | 287 10.2 / 3.90 | 328 11.8 / 5.54 | 365 13.5 / 7.35 | 400 14.9 / 9.30 | 432 16.2 / 11.37 | 462 17.9 / 13.54 | | |
28000 | 264 9.2 / 3.14 | 312 11.2 / 5.04 | 350 12.8 / 6.83 | 384 14.3 / 8.75 | 417 15.6 / 10.83 | 447 16.9 / 13.03 | | | |
31000 | 293 10.4 / 4.26 | 337 12.2 / 6.39 | 372 13.7 / 8.35 | 404 15.1 / 10.41 | 435 16.3 / 12.60 | 464 18.0 / 14.92 | | | |
34000 | 321 11.6 / 5.62 | 362 13.3 / 8.00 | 395 14.7 / 10.14 | 426 15.9 / 12.34 | 455 17.4 / 14.66 | | | | |
37000 | 349 12.8 / 7.24 | 388 14.4 / 9.87 | 419 15.7 / 12.21 | 448 17.1 / 14.56 | | | | | |
40000 | 377 14.0 / 9.14 | 414 15.5 / 12.04 | 444 18.5 / 14.58 | | | | | | |
43000 | 406 15.2 / 11.36 | 440 20 / 14.51 | | | | | | | |
46000 | 434 16.2 / 13.90 | | | | | | | | |
|
Performance shown is certified for installation type A: Free inlet, Free outlet.
Performance ratings do not include the effects of appurtenances in the airstream.
Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness
values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA
Standard 301. Values shown are for Installation Type A: free inlet fan sone levels.
|