Performance Table
CFMStatic Pressure in Inches W.G.
0.0000.2500.5000.7501.0001.5002.0002.500
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
8001110
6.4 / 0.09
1286
8.1 / 0.15
1429
9.3 / 0.21
1562
10.7 / 0.28
1688
11.8 / 0.35
1928
14.0 / 0.51
2145
15.9 / 0.67
2353
18.2 / 0.86
10001387
8.9 / 0.17
1536
10.3 / 0.24
1661
11.5 / 0.32
1773
12.5 / 0.40
1880
13.3 / 0.48
2088
15.4 / 0.66
2283
17.4 / 0.85
 
 
12001664
11.9 / 0.29
1794
13.2 / 0.38
1905
13.5 / 0.47
2003
14.2 / 0.56
2098
15.2 / 0.65
2277
17.1 / 0.85
 
 
 
 
14001942
14.5 / 0.46
2056
15.7 / 0.56
2154
16.1 / 0.66
2244
17.4 / 0.77
2329
18.2 / 0.88
 
 
 
 
 
 
16002219
18.0 / 0.68
2322
19.5 / 0.80
2413
20 / 0.92
 
 
 
 
 
 
 
 
 
18002497
22 / 0.97
 
 
 
 
 
 
 
 
   
Performance shown is certified for installation type B:  Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (BHP) includes transmission losses. The sound ratings shown are loudness values in sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type B: free inlet fan sone levels. Ratings do not include the effect of duct end correction.