Performance Table |
CFM | Static Pressure in Inches W.G. |
---|
0.000 | 0.250 | 0.500 | 0.750 | 1.000 | 1.500 | 2.000 | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP |
2500 | 470 5.6 / 0.10 | 605 5.7 / 0.26 | 734 8.0 / 0.45 | 851 9.7 / 0.68 | | | |
3000 | 563 7.6 / 0.18 | 678 7.1 / 0.35 | 787 9.0 / 0.56 | 893 10.5 / 0.81 | 991 12.5 / 1.08 | | |
3500 | 657 9.8 / 0.28 | 757 9.2 / 0.48 | 851 10.1 / 0.71 | 944 11.5 / 0.97 | 1034 13.3 / 1.27 | 1201 16.9 / 1.89 | |
4000 | 751 12.4 / 0.42 | 840 9.9 / 0.65 | 923 11.4 / 0.89 | 1005 13.0 / 1.17 | 1086 14.5 / 1.48 | 1241 17.7 / 2.16 | 1384 22 / 2.89 |
4500 | 845 12.5 / 0.59 | 925 11.3 / 0.85 | 999 12.6 / 1.12 | 1072 14.4 / 1.42 | 1145 15.8 / 1.74 | 1288 18.9 / 2.45 | |
5000 | 939 14.3 / 0.81 | 1012 15.8 / 1.10 | 1079 14.1 / 1.39 | 1145 15.4 / 1.71 | 1211 16.9 / 2.04 | 1341 21 / 2.79 | |
5500 | 1032 16.2 / 1.08 | 1100 17.7 / 1.39 | 1162 15.8 / 1.71 | 1222 17.2 / 2.05 | 1282 18.5 / 2.41 | | |
6000 | 1126 18.2 / 1.41 | 1189 19.8 / 1.75 | 1246 17.6 / 2.09 | 1302 18.9 / 2.45 | 1357 20 / 2.82 | | |
6500 | 1220 21 / 1.79 | 1279 22 / 2.16 | 1332 23 / 2.53 | 1384 23 / 2.91 | | | |
7000 | 1314 23 / 2.23 | 1369 25 / 2.63 | | | | | |
7500 | 1408 27 / 2.75 | | | | | | |
|
Performance shown is certified for installation type B: Free inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances in the airstream.
Power rating (BHP) includes transmission losses. The sound ratings
shown are loudness values in sones at 5 ft (1.5m) in a
hemispherical free field calculated per AMCA Standard 301.
Values shown are for Installation Type B: free inlet fan sone levels.
Ratings do not include the effect of duct end correction.
|