DDAR-FA Performance Table
Model | Motor HP |
RPM | TS | Static Pressure in Inches W.G. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.000 | 0.125 | 0.250 | 0.375 | 0.500 | 0.625 | 0.750 | 0.875 | 1.000 | 1.125 | ||||
DDAR10FA | 1/30 | 1500 | 3927 | 524 | 333 | 226 | 120 | ||||||
DDAR12FA | 1/10 | 1500 | 4712 | 830 | 710 | 620 | 522 | 436 | 357 | 270 | 175 | 78 | |
DDAR14FA | 1/6 | 1100 | 4032 | 1008 | 570 | 372 | 197 | 10 | |||||
DDAR18FA | 1/3 | 1100 | 5184 | 2400 | 2034 | 1628 | 1491 | 1293 | 1084 | 881 | 662 | 433 | 176 |
Performance shown is certified for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (BHP) does not include transmission losses. |
||
CaptiveAire certifies that Models DDAR10FA through DDAR18FA are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and complies with the requirements of the AMCA Certified Ratings Program. Tested to AMCA Standards 210. Meets California Energy Commission (CEC) Title 20 Regulations. |
|
|
Catalog #110C | ||
May 2024 |