� Fully Integrated Self Cleaning Hood
|
Manifolds and Electrical controls are directly mounted in a utility cabinet on the side of the
hood. All piping and wiring are done in the factory to minimize labor at the job site.
|
|
The operation is intuitive: At the beginning of the day the fan switch is turned ON and the
fans start running. At the end of the day, when the cooking is done, the fan switch is turned OFF,
the fans shut off and the Hot water Wash Cycle automatically starts.
|
|
|
- W1 = Hot Water Wash
- W2 = Cold Water Mist
- W3 = Cold Water Mist and Hot Water Wash
- W4 = Hot Water Wash with addition of Energy Management System (EMS)
- W1REMOTE = Additional manifold if needed for Hot Water Wash
- W2REMOTE = Additional manifold if needed for Cold Water Mist
- W3REMOTE = Additional manifold if needed for Hot Water Wash and Cold Water Mist
|
|
|
|
|
If the application design does not allow for utility cabinets on the end of the hoods, then manifolds
can be ordered in a remote cabinet and piped to the hood at the jobsite.
|
|
The control panel includes a combination pressure/temperature gauge, shock absorber, pressure
reducing valve, water solenoid valve, surfactant pump, line strainer, gate valve and surfactant tank.
|
|
When selected, the hot water option, will provide a 3-minute wash down of the plenum and the ductwork
immediately following. Surfactant will be injected into the wash for one second, every one minute of the
cycle. Both the wash and the surfactant injection times are adjustable to meet the needs of every application.
|
|
Two versions of this panel are available. The
AM-2 with
simple controls and the SCS panel with
more advanced features. The SCS panel with its touch screen interface allows for multiple wash zones,
programmable schedule and web interface.
|
|
Selectable options:
- 3/4", 1" or 1.5" Manifold 3/4" should be used up to 16’ of hood, 1" up to 30’ of hood and 1.5" up to 48’ of hood
- Hot Water wash, Cold Water Mist or Both
- Backflow Preventer
|
|
The AM-2 Control panel houses a plumbing enclosure providing Self Cleaning operation for ventilation hood.
ETL Listed. Complies with UL508A Standards and C22.2, No. 14-M95 and CSA 22.2, No. 73-1953 Standards.
AM-2 panel can be ordered in conjunction with a prewire for full control of the fans and wash cycle. (M40000D)
It can also be ordered with starter coil control only for both exhaust and supply fans; others provide the starters. (M41000)
|
|
|
- ETL Listed Product
- Easily serviceable
- Adjustable surfactant injection timing and volume (factory set for 1 second injection with 1 minute delay)
- Adjustable wash length (factory set at 3 minutes)
- 3/4", 1" and 1 1/2" manifolds available based on application
- Replacement parts and surfactant available from the CaptiveAire catalog
- Backflow preventer (optional)
- Starter Coil control for exhaust and supply fans are available
- Tie-in with demand ventilation controls available (hot water wash only)
|
|
|
|
Hood Length |
Hot Water Line Size @ 20 psi |
Up to 16 ft |
3/4" ips |
16 - 32 ft |
1" ips |
32 - 48 ft |
1 1/2" ips |
|
|
|
The AM-2 Model has been certified by ITS. This certification mark indicates that
the product has been tested to and has met the minimum requirements of a widely recognized
(consensus) U.S. and Canadian products safety standard, that the manufacturing site
has been audited, and that the applicant has agreed to a program of periodic factory
follow-up inspections to verify continued performance.
|
|
|
Models AM-2 are ETL Listed under file number 3054731-001 and complies with
UL508A Standards and CSA C22.2, No. 14-M95 and CSA C22.2, No. 73-1953 Standards.
|
|
Self-Cleaning System Panel
|
The Self Cleaning System (SCS) includes a state-of-the-art controller and
touch screen for ultimate control of Self Cleaning operation for the ventilation hood. The
touch screen, located on the front of the panel allows for user-friendly programming. For the
controls, the SCS uses a Programmable Logic Controller (PLC) which also serves as a web server.
|
|
The smart controls allow for:
- Programmable schedules for fans and Wash
- Building Management (BMS) Control
- Multiple wash Zones
- PCU Pressure switch connection for filter change indication (visual and audible with mute function)
- Electric Gas Valve Connection (integrated Reset Relay logic)
- Web interface for easy access to schedules and to control hood operations
- FP Option
|
|
|
- ETL Listed Product
- Easily programmable wash scheduling
- Adjustable surfactant injection timing and volume (factory set for 1 second injection with 1 minute delay)
- Adjustable wash length (factory set at 3 minutes)
- 3/4", 1" and 1 1/2" inch manifolds available based on application
- Replacement parts and surfactant available from the CaptiveAire catalog
- Backflow preventer (optional)
|
|
|
Hood Length |
Water Line Size |
3’ - 16’ |
3/4" IPS |
16’1" - 32’ |
1" IPS |
32’1" - 48’ |
1 1/2" IPS |
|
|
|
The SCS Model has been certified by ITS. This certification mark indicates that the
product has been tested to and has met the minimum requirements of a widely recognized
(consensus) U.S. and Canadian products safety standard, that the manufacturing site has
been audited, and that the applicant has agreed to a program of periodic factory follow-up
inspections to verify continued performance.
Models SCS are ETL Listed under file number 3054731-001 and complies with UL508A Standards
and CSA C22.2, No. 14-M95 and CSA C22.2, No. 73-1953 Standards.
|
![](/images/etl/etl_can-us_4.gif)
|
|