AM-SCA-N Series
|
|
Water Wash Exhaust Ventilator with Back Supply Air Plenum
|
AquaMatic's ETL Listed AM-SCA-N canopy style exhaust ventilator utilizes high velocity
slot type grease extraction with automatic internal water wash system and integrated
wash and rinse cycles. The back supply air plenum provides up to 90% make-up air.
The AM-SCA-N is a Type 1 exhaust canopy utilizing
high velocity slot type grease extraction with an automatic internal water wash system,
and integrated wash and rinse cycles.
The AM-SCA-N is suitable for wall mounted, back-to-back, or single island applications.
The ventilator is capable of providing up to 90% make-up air through a stainless steel back plenum.
|
|
|
- ETL Listed and ETL Sanitation Listed Product
- Automatic Internal Water Wash System
- Choice of Electromechanical or Solid State Programmable Control Panels
- Superior Exhaust Flow Rates
- Exceptional Capture and Containment of Cooking Vapors
- Wall, Single Island, or Back-to-Back Configurations
- 100% Type 304 Stainless Steel Construction
- Front Exposed Corners Ground and Polished to Match Grain of Ventilator
- Double Wall, Insulated Front
- Grease Extracting Cartridges
- Grease Drain System
- Removable Access Doors for Exhaust Plenum Access
- Pre-punched Hanging Angles
- Factory Pre-wired Lighting
- Face Mounted Light Switches Optional
- Back Supply Air Plenum Features:
-- 90% Make-Up Air Delivery with a Maximum of 200 CFM/ft
-- Stainless Steel Construction to Match Ventilator
-- Creates Positive Pressure Barrier to Keep Smoke and Grease
Laden Vapors
Moving Upward Toward Ventilator
|
|
|
AM-2 Control Panel provides push button operation with relay control of the
exhaust and make-up air fans as well as the cleaning cycle of the ventilator
hood. The time period of the rinse cycle is adjustable up to 3 minutes. The
control panel includes a combination pressure/temperature gauge, shock
absorber, pressure reducing valve, water solenoid valve, detergent pump,
line strainer, and gate valve. See product specification sheet for details.
|
|
|
- Utility Cabinet
- Fire Suppression System
- Electrical Controls
- Front Perforated Linear Supply Air Plenum (PLS)
- Integral Face Discharge Make-Up Air
- Dry Slot with No Internal Wash System
- Cold Water Mist
- ETL Listed Exhaust Fire Damper
- Enclosure Panels to Ceiling
- End Panels
- Lighting:
-- Recessed Incandescent
-- Recessed Fluorescent
- Roof Top Packages
- Exhaust Fans
- Make-Up Air Units:
-- Untempered Units
-- Direct Gas Fired Heated Units
-- Indirect Gas Fired Heated Units
-- Electric Heated Units
-- Heating & Cooling Coils
|
|
|
AquaMatic� offers a total system to insure maximum installation and operating
efficiencies. Components consist of the ventilator, fire system and electrical
controls contained within an integral utility cabinet, and fan packages including
exhaust, untempered and tempered make-up air packages. Also available are air
purification and energy management systems. Fire suppression systems include
final hookup and inspection. Call your AquaMatic Representative for more details.
|
|
|
600�F - Ovens, Steamers, Kettles,
Open-Burner Ranges, Griddles, Fryers, Gas Charbroilers, Electric Charbroilers
|
Single Wall Hood
2 Wall Hoods Back-to-Back |
250
500 |
225
450 |
|
|
|
Application
The ventilator shall provide flexibility in designing kitchen ventilation
equipment and shall be tested and listed for use over light, medium and
heavy duty cooking surfaces, maximum 600�F.
Construction
The ventilator shall be 100% constructed of Type 304 stainless steel with #3 or #4
polish. All seams shall be welded or in conformance with ETL standards. Front
exposed corners shall be ground and polished to match the ventilator grain.
Individual component construction shall be determined by manufacturer and ETL.
Construction shall be dependent on the structural application to minimize
distortion and other defects. All seams, joints and penetrations of the ventilator
where grease-laden vapors and exhaust gases are present, must be liquid-tight,
continuous welds in accordance with NFPA 96.
The ventilator shall be constructed to include:
- A double wall insulated front to eliminate condensation and increase
rigidity. The insulation shall have a flexural modulus of 475 EI, meet
UL 181 requirements and be in accordance with NFPA 90A and 90B.
- A full length, horizontal exhaust inlet slot and a series of fixed
baffles for grease removal.
- An integral front baffle to direct grease-laden vapors toward the exhaust
filter bank.
- An integral drain system on the ventilator back. Multiple end-to-end
ventilators can be manifolded to one common drain.
- Stainless steel back supply air plenum to provide
make-up air through stainless steel perforated panels, discharged below the cooking
equipment. Steel diffuser plates are designed to provide even air distribution.
- A built-in wiring chase for electrical controls on the front face of the
ventilator designed to avoid penetration of the capture area and eliminate
the need for an external chaseway.
- UL incandescent light fixtures and globes, allowing up to a 100 watt
standard light bulb, installed and pre-wired to a junction box and installed
with a maximum of 3'-6" spacing on center.
- Exhaust duct collar 5" high with 1" flange.
- A minimum of four connections for hanger rods. Connectors shall
have 9/16" holes pre-punched in 1 1/2" x 1 1/2" angle iron at the factory to
allow for hanger rod connection by others.
- Heavy duty, removable grease extracting cartridge, with size and
quantity determined by the hood's dimensional parameters, not to exceed
60" in length.
Certifications
The ventilator shall be ETL Listed as "Exhaust Hoods Without Exhaust Damper", ETL Listed
to Canadian Safety Standards, ETL Sanitation Listed and built in accordance with NFPA 96.
Documentation
Manufacturer shall furnish complete computer generated submittal drawings including
ventilator section view(s), plan view(s), duct sizing, and CFM and static pressure
requirements. Static pressure, air velocity and air volume requirements indicated
on drawings shall be precise and accurate and ventilator shall preform to said
specifications. Drawings shall be available to the engineer, architect and owner
for their use in construction, operation and maintenance.
|
|
|
|
|
|
|
|
|
The AM-SCA-N Model has been certified by ITS. This certification mark indicates that
the product has been tested to and has met the minimum requirements of a widely recognized
(consensus) U.S. and Canadian products safety standard, that the manufacturing site
has been audited, and that the applicant has agreed to a program of periodic factory
follow-up inspections to verify continued performance.
|
|
|
Models AM-SCA-N are ETL Listed under file number 3054804-001 and complies with UL710, ULC710 and ULC-S646 Standards.
|
|
|