AM-VHC Series
|
|
Single Wall Exhaust Ventilator
|
AquaMatic's AM-VHC ventilator is an exhaust only unit to be used over
non-grease producing equipment. Baffles are utilized for extreme steam
applications.
The AM-VHC is a Type 2, wall mounted, single island or double island,
exhaust canopy used for non-grease applications for the removal of
steam, vapor, heat and odors where grease is not present.
|
|
|
- ETL Sanitation Listed Product
- Excellent Exhaust Flow Rates
- Exceptional Capture and Containment of Cooking Vapors
- Wall, Single Island or Double Island Configurations
- 100% Type 304 Stainless Steel Construction
- Exposed Corners Ground and Polished to Match Grain of Ventilator
- Pre-punched Hanging Angles
- Integral Front and Back Condensate Gutter and Drain
- Top and Removable Side Stainless Baffle Plates
|
|
|
- Condensate Perimeter Gutter and Single Drain
- Perforated Linear Supply Air Plenum (PLS)
- Enclosure Panels to Ceiling
- Roof Top Packages
- Exhaust Fans
- Make-Up Air Units:
-- Untempered Units
-- Direct Gas Fired Heated Units
-- Indirect Gas Fired Heated Units
-- Electric Heated Units
-- Heating & Cooling Coils
|
|
|
AquaMatic® offers a total system to insure maximum installation and operating
efficiencies. Components consist of the ventilator, fire system and electrical
controls contained within an integral utility cabinet, and fan packages including
exhaust, untempered and tempered make-up air packages. Also available are air
purification and energy management systems. Fire suppression systems include
final hookup and inspection. Call your AquaMatic Representative for more details.
|
|
|
Light - Ovens, Rotisseries |
Wall Hood 1 Piece Island |
100 100 |
Exhaust - Based
on 1500 FPM |
Heavy - Dishwashers |
Wall Hood 1 Piece Island |
150 150 |
|
|
|
Application
The ventilator is ETL Sanitation Listed for use over non-grease applications, specifically
for the removal of steam, vapor, heat and odors. The ventilator shall be
used over dishwashers, steam tables, ovens, steamers or kettles if they
do not produce smoke or grease-laden vapors, subject to approval of the
authority having jurisdiction.
Construction
The ventilator shall be 100% constructed of Type 304 stainless steel with
#3 or #4 polish. Front seams shall be welded. All exposed corners shall be
ground and to match the ventilator grain.
The ventilator shall be constructed to include:
- Exhaust duct collar 4" high with 1" flange.
- A minimum of four connections for hanger rods. Connectors shall
have 9/16" holes pre-punched in 1 1/2" x 1 1/2" angle iron at the factory to
allow for hanger rod connection by others.
Certifications
The ventilator shall be ETL Sanitation Listed.
Documentation
Manufacturer shall furnish complete computer generated submittal drawings including
ventilator section view(s), plan view(s), duct sizing, and CFM and static pressure
requirements. Static pressure, air velocity and air volume requirements indicated
on drawings shall be precise and accurate and ventilator shall preform to said
specifications. Drawings shall be available to the engineer, architect and owner
for their use in construction, operation and maintenance.
|
|
|
|
|
|
|