Performance Table
CFMStatic Pressure in Inches W.G.
0.0000.2500.5000.7501.0001.500
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
RPM
Sone/BHP
2000862
8.2 / 0.17
1027
10.2 / 0.32
1165
11.2 / 0.47
1283
12.7 / 0.64
1391
14.1 / 0.81
1589
16.9 / 1.18
25001078
10.8 / 0.34
1211
11.9 / 0.52
1335
13.3 / 0.71
1443
14.7 / 0.90
1540
16.2 / 1.10
 
 
30001293
13.2 / 0.58
1404
14.2 / 0.79
1514
15.2 / 1.02
1614
16.3 / 1.25
1705
17.6 / 1.48
 
 
35001509
15.3 / 0.93
1603
16.7 / 1.17
1700
17.9 / 1.43
 
 
 
 
 
40001724
18.4 / 1.38
 
 
 
 
 
 
  
Performance shown is certified for installation type B:  Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating (BHP) includes transmission losses. The sound ratings shown are loudness values in sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type B: free inlet fan sone levels. Ratings do not include the effect of duct end correction.