Performance Table |
CFM | Static Pressure in Inches W.G. |
---|
0.000 | 0.250 | 0.500 | 0.750 | 1.000 | 1.500 | 2.000 | 2.500 | 3.000 | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP |
4000 | 675 9.2 / 0.45 | 750 10.4 / 0.70 | 819 11.5 / 0.95 | 883 12.7 / 1.21 | 943 14.1 / 1.48 | 1054 18.8 / 2.06 | 1156 21 / 2.70 | 1250 22 / 3.37 | 1340 24 / 4.09 |
5000 | 843 12.5 / 0.88 | 905 13.2 / 1.20 | 962 14.7 / 1.50 | 1017 16.5 / 1.81 | 1069 18.8 / 2.13 | 1167 21 / 2.80 | 1258 22 / 3.51 | 1344 24 / 4.27 | 1425 25 / 5.06 |
6000 | 1012 16.5 / 1.52 | 1064 16.6 / 1.90 | 1113 20 / 2.27 | 1161 21 / 2.64 | 1206 21 / 3.01 | 1293 23 / 3.78 | 1376 24 / 4.58 | 1453 26 / 5.41 | 1528 28 / 6.29 |
7000 | 1180 21 / 2.41 | 1225 20 / 2.86 | 1269 21 / 3.30 | 1310 23 / 3.73 | 1351 24 / 4.16 | 1428 25 / 5.03 | 1503 27 / 5.93 | 1574 29 / 6.85 | |
8000 | 1349 26 / 3.60 | 1388 24 / 4.12 | 1427 24 / 4.62 | 1464 26 / 5.11 | 1500 27 / 5.61 | 1570 29 / 6.59 | | | |
9000 | 1517 30 / 5.12 | 1553 29 / 5.71 | 1587 30 / 6.28 | 1621 30 / 6.84 | 1653 31 / 7.39 | | | | |
10000 | 1686 32 / 7.03 | | | | | | | | |
|
Performance shown is certified for installation type B: Free inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances in the airstream.
Power rating (BHP) includes transmission losses. The sound ratings
shown are loudness values in sones at 5 ft (1.5m) in a
hemispherical free field calculated per AMCA Standard 301.
Values shown are for Installation Type B: free inlet fan sone levels.
Ratings do not include the effect of duct end correction.
|