Performance Table |
CFM | Static Pressure in Inches W.G. |
---|
0.000 | 0.250 | 0.500 | 0.750 | 1.000 | 1.250 | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP | RPM Sone/BHP |
1400 | 896 7.2 / 0.09 | 1017 9.1 / 0.16 | 1135 11.5 / 0.23 | 1252 12.1 / 0.31 | 1367 14.4 / 0.40 | 1480 15.7 / 0.50 |
1600 | 1024 9.9 / 0.14 | 1131 11.9 / 0.21 | 1235 13.9 / 0.29 | 1338 14.9 / 0.38 | 1439 15.8 / 0.48 | |
1800 | 1152 13.1 / 0.20 | 1247 14.6 / 0.28 | 1340 15.4 / 0.37 | 1432 16.6 / 0.46 | | |
2000 | 1280 14.8 / 0.28 | 1366 17.1 / 0.36 | 1450 17.9 / 0.46 | | | |
2200 | 1408 18.7 / 0.37 | 1486 19.4 / 0.46 | | | | |
2400 | 1536 21 / 0.48 | | | | | |
|
Performance shown is for installation type A: Free inlet, Free outlet.
Performance ratings do not include the effects of appurtenances in the airstream.
Power rating (BHP) does not include drive losses. The sound ratings shown are loudness
values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA
Standard 301. Values shown are for Installation Type A: free inlet fan sone levels.
|