Lookup Part! - 1300141
|
BURNER-HMA-2A 24" Assembled with bottom inlet. Does not include pilot assembly.
Aluminum Casting.
|
|
|
Lookup Part! - 5BVVTH
|
5'' DuraVent Type B High-Wind Cap. High Wind B Vent cap meets the UL standard for "high Wind" which is a 45 MPH test. Direct replacement for part number 5RHW and 5GVVTH.
|
Used In
|
|
|
|
|
|
|
|
Lookup Part! - 90416
|
High Temp Silicone Rubber Tubing for IBT power vent. Durometer=50, .25" OD, .125" ID, 450°F Max continuous temperature. Sold Per foot.
|
Used In
|
|
|
Lookup Part! - IBT1000-300-300-400
|
Bent Tube Furnaces - 1,000,000 BTU/HR maximum input, 800,000 BTU/HR maximum output, 40,000 BTU/HR minimum output for NG, 48,000 BTU/Hr minimum output for LP.
Includes (2) 300 and (1) 400 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2,3,4, and 5 IBT.
|
|
|
Lookup Part! - IBT1200-400-400-400
|
Bent Tube Furnaces - 1,200,000 BTU/HR maximum input, 960,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (3) 400 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3,4, and 5 IBT.
|
|
|
Lookup Part! - IBT1400-300-300-400-400
|
Bent Tube Furnaces - 1,400,000 BTU/HR maximum input, 1,120,000 BTU/HR maximum output, 40,000 BTU/HR minimum output for NG, 48,000 BTU/HR minimum output for LP.
Includes (2) 300 and (2) 400 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2,3,4, and 5 IBT.
|
|
|
Lookup Part! - IBT150
|
Bent Tube Furnace - 150,000 BTU/HR maximum input, 120,000 BTU/HR maximum output, 20,000 BTU/HR minimum output for NG, 24,000 BTU/HR minimum output for LP.
Includes (1) 150 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 IBT.
|
|
|
Lookup Part! - IBT1600-400-400-400-400
|
Bent Tube Furnaces - 1,600,000 BTU/HR maximum input, 1,280,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (4) 400 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 and 5 IBT.
|
|
|
Lookup Part! - IBT200
|
Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 and 2 IBT.
|
|
|
Lookup Part! - IBT300
|
Bent Tube Furnace - 300,000 BTU/HR maximum input, 240,000 BTU/HR maximum output, 40,000 BTU/HR minimum output for NG, 48,000 BTU/HR minimum output for LP.
Includes (1) 300 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2 IBT.
|
|
|
Lookup Part! - IBT300-150-150
|
Bent Tube Furnaces - 300,000 BTU/HR maximum input, 240,000 BTU/HR maximum output, 20,000 BTU/HR minimum output for NG, 24,000 BTU/HR minimum output for LP.
Includes (2) 150 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 IBT.
|
|
|
Lookup Part! - IBT400-200-200
|
Bent Tube Furnaces - 400,000 BTU/HR maximum input, 320,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP.
Includes (2) 200 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 and 2 IBT.
|
|
|
Lookup Part! - IBT600-300-300
|
Bent Tube Furnaces - 600,000 BTU/HR maximum input, 480,000 BTU/HR maximum output, 40,000 BTU/HR minimum output for NG, 48,000 BTU/HR minimum output for LP.
Includes (2) 300 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2 and 3 IBT.
|
|
|
Lookup Part! - IBT800-400-400
|
Bent Tube Furnaces - 800,000 BTU/HR maximum input, 640,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (2) 400 MBH Input Furnaces.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2,3,4, and 5 IBT.
|
|
|
|
|
|
|
Lookup Part! - RTU150HE
|
90% High Efficiency Bent Tube Furnace - 150,000 BTU/HR maximum input, 135,000 BTU/HR maximum output, 22500 BTU/HR minimum output for NG, 27000 BTU/HR minimum output for LP.
Includes (1) 150 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2,3 RTU
|
|
|
Lookup Part! - RTU150HE-1
|
90% High Efficiency Bent Tube Furnace - 150,000 BTU/HR maximum input, 135,000 BTU/HR maximum output, 22500 BTU/HR minimum output for NG, 27000 BTU/HR minimum output for LP.
Includes (1) 150 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 RTU
|
|
|
Lookup Part! - RTU200
|
Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2 and 3 RTU
|
|
|
Lookup Part! - RTU200-1
|
Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 RTU
|
|
|
Lookup Part! - RTU200A
|
Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) HMA 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU
|
|
|
Lookup Part! - RTU200AHT
|
High Turndown Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) HMA 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU
|
|
|
Lookup Part! - RTU200HE
|
90% High Efficiency Bent Tube Furnace - 200,000 BTU/HR maximum input, 180,000 BTU/HR maximum output, 30000 BTU/HR minimum output for NG, 36,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2 and 3 RTU
|
|
|
Lookup Part! - RTU200HE-1
|
90% High Efficiency Bent Tube Furnace - 200,000 BTU/HR maximum input, 180,000 BTU/HR maximum output, 30000 BTU/HR minimum output for NG, 36,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 1 RTU
|
|
|
Lookup Part! - RTU200HT
|
High Turndown Bent Tube Furnace - 200,000 BTU/HR maximum input, 160,000 BTU/HR maximum output, 26,667 BTU/HR minimum output for NG, 32,000 BTU/HR minimum output for LP. Includes (1) 200 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2 and 3 RTU
|
|
|
Lookup Part! - RTU250
|
Bent Tube Furnace - 250,000 BTU/HR maximum input, 200,000 BTU/HR maximum output, 33,333 BTU/HR minimum output for NG, 40,000 BTU/HR minimum output for LP. Includes (1) 250 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No controls or sheet metal housing.
Used in size 2 and 3 RTU
|
|
|
Lookup Part! - RTU250HE
|
90% High Efficiency Bent Tube Furnace - 250,000 BTU/HR maximum input, 225,000 BTU/HR maximum output, 30000 BTU/HR minimum output for NG, 36,000 BTU/HR minimum output for LP. Includes (1) 250 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 2 and 3 RTU
|
|
|
Lookup Part! - RTU250HT
|
High Turndown Bent Tube Furnace - 250,000 BTU/HR maximum input, 200,000 BTU/HR maximum output, 16,667 BTU/HR minimum output for NG, 20,833 BTU/HR minimum output for LP. Includes (1) 250 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No controls or sheet metal housing.
Used in size 2 and 3 RTU
|
|
|
Lookup Part! - RTU300HE
|
High Efficiency Bent Tube Furnace - 300,000 BTU/HR maximum input, 270,000 BTU/HR maximum output, 45,000 BTU/HR minimum output for NG, 54,000 BTU/HR minimum output for LP.
Includes (1) 300 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3 RTU
|
|
|
Lookup Part! - RTU400
|
Bent Tube Furnace - 400,000 BTU/HR maximum input, 320,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (1) 400 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3 RTU.
|
|
|
Lookup Part! - RTU400A
|
Bent Tube Furnace - 400,000 BTU/HR maximum input, 320,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (1) HMA 400 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU400AHT
|
High Turndown Bent Tube Furnace - 400,000 BTU/HR maximum input, 320,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (1) HMA 400 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU400HE
|
90% High Efficiency Bent Tube Furnace - 400,000 BTU/HR maximum input, 360,000 BTU/HR maximum output, 60,000 BTU/HR minimum output for NG, 72,000 BTU/HR minimum output for LP.
Includes (1) 400 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3 RTU.
|
|
|
Lookup Part! - RTU400HT
|
High Turndown Bent Tube Furnace - 400,000 BTU/HR maximum input, 320,000 BTU/HR maximum output, 21,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (1) 400 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3 RTU.
|
|
|
Lookup Part! - RTU500
|
Bent Tube Furnace - 500,000 BTU/HR maximum input, 400,000 BTU/HR maximum output, 66,666 BTU/HR minimum output for NG, 80,000 BTU/HR minimum output for LP.
Includes (1) 500 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3 RTU.
|
|
|
Lookup Part! - RTU500A
|
Bent Tube Furnace - 500,000 BTU/HR maximum input, 400,000 BTU/HR maximum output, 66,667 BTU/HR minimum output for NG, 80,000 BTU/HR minimum output for LP.
Includes (1) HMA 500 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU500AHT
|
High Turndown Bent Tube Furnace - 500,000 BTU/HR maximum input, 400,000 BTU/HR maximum output, 66,667 BTU/HR minimum output for NG, 80,000 BTU/HR minimum output for LP.
Includes (1) HMA 500 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU500HT
|
High Turndown Bent Tube Furnace - 500,000 BTU/HR maximum input, 400,000 BTU/HR maximum output, 66,666 BTU/HR minimum output for NG, 80,000 BTU/HR minimum output for LP.
Includes (1) 500 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 3 RTU.
|
|
|
Lookup Part! - RTU600A
|
Bent Tube Furnace - 600,000 BTU/HR maximum input, 480,000 BTU/HR maximum output, 80,000 BTU/HR minimum output for NG, 96,000 BTU/HR minimum output for LP.
Includes (1) HMA 600 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU600AHT
|
High Turndown Bent Tube Furnace - 600,000 BTU/HR maximum input, 480,000 BTU/HR maximum output, 80,000 BTU/HR minimum output for NG, 96,000 BTU/HR minimum output for LP.
Includes (1) HMA 600 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and Power Vent.
No contols or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU700A
|
Bent Tube Furnace - 700,000 BTU/HR maximum input, 560,000 BTU/HR maximum output, 58,333 BTU/HR minimum output for NG, 70,000 BTU/HR minimum output for LP.
Includes (1) HMA 700 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and (2) Power Vents.
No controls or sheet metal housing.
Used in size 4 RTU.
|
|
|
Lookup Part! - RTU800A
|
Bent Tube Furnace - 800,000 BTU/HR maximum input, 640,000 BTU/HR maximum output, 53,333 BTU/HR minimum output for NG, 64,000 BTU/HR minimum output for LP.
Includes (1) HMA 800 MBH Input Furnace.
Stainless Steel Burner, Heat Exchanger, and (2) Power Vents.
No controls or sheet metal housing.
Used in size 4 RTU.
|
|
|
|
|
|