DX Cooling Coil Module (Sizes 1-2)
|
Lookup Part! - DXM1-1
|
DX Coil Module for Size 1 Modular Fans - 1,000 thru 3,250 CFM (3 Ton - 1 Circuit DX Coil, 3EZ0802H-31.5X27.0) NOT BUILT WITH OPPOSITE SIDE CONTROLS. DXM1-1
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EN0603B-31.5x27.0)
|
|
|
Lookup Part! - DXM1-2
|
DX Coil Module for Size 1 Modular Fans - 1,000 thru 3,250 CFM (5 Ton - 1 Circuit DX Coil, 4EZ0802H-31.5x27.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM1-2
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EN0903B-31.5x27.0)
|
|
|
Lookup Part! - DXM1-3
|
DX Coil Module for Size 1 Modular Fans - 2,000 thru 3,250 CFM (10 Ton - 2 Circuit DX Coil, 4EZ0903H-31.5x27.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM1-3
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0804B-31.5x27.0)
|
|
|
Lookup Part! - DXM1-4
|
DX Coil Module for Size 1 Modular Fans - 2,500 thru 3,250 CFM (12.5 Ton - 2 Circuit DX Coil, 3EZ1303H-31.5x27.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM1-4
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ1304B-31.5x27.0)
|
|
|
Lookup Part! - DXM2-1
|
DX Coil Module for Size 2 Modular Fans - 1,500 thru 5,300 CFM (5 Ton - 2 Circuit DX Coil, 3EZ1201H-37.5x36.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM2-1
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0603B-37.5x36.0)
|
|
|
Lookup Part! - DXM2-2
|
DX Coil Module for Size 2 Modular Fans - 2,000 thru 5,300 CFM (10 Ton - 2 Circuit DX Coil, 4EZ1002H-37.5x36.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM2-2
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ0703B-37.5x36.0)
|
|
|
Lookup Part! - DXM2-3
|
DX Coil Module for Size 2 Modular Fans - 3,000 thru 5,300 CFM (15 Ton - 2 Circuit DX Coil, 4EY1002H-37.5x36.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM2-3
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil # 5EJ1103B-37.5x36.0)
|
|
|
Lookup Part! - DXM2-4
|
DX Coil Module for Size 2 Modular Fans - 4,000 thru 5,300 CFM (20 Ton - 2 Circuit DX Coil, 4EZ0903C-37.5x36.0) NOT BUILT WITH OPP SIDE CONTROLS. DXM2-4
Condenser and condenser disconnect (unless provided on quote) will be installed, started and warranted by others. R410A refrigerant and piping by others. Ensure DX-Kit is ordered for filter drier, sight glass, thermal expansion valve. (Old Heatcraft Coil Coil # 5EJ0904B-37.5x36.0)
|
|
|
|